Setback chart for setback of retaining wall

Setback chart for Terraforce retaining blocks

Apart from following the installation guidelines as set out by Terraforce, it is also strongly advisable to consult the setback chart provided to achieve desired (or necessary) setback of your retaining wall.

To check your possible wall height for a single skin wall, consult the design tables (on the design planning page) for Terraforce products.

Setback chart
Block height mm

Wall angle ß

225

Setback mm

210

Setback mm

200

Setback mm

150

Setback mm

50189176168128
55158147140106
6013012111588
65105989371
7082767355
7560565441
8040373527
8520181713