Design table - Terraforce L16 Block

Maximum wall heights (in block height, metres, feet) for a single skin, mass gravity, block retaining wall system - without additional interlocking keys, reinforcements or backfill stabilizing.

Retained Soil Backslope above crest
of retaining wall
Wall inclination from horizontal
 
60° 65° 70° 75° 80° 85° 90° inclination
115 93 73 54 35 17 0 mm setback
4.5 3.7 2.9 2.1 1.4 0.7 0 " setback
Firm clay
&
compact silt
0
15.9 12.7 9.9 7.6 5.8 4.4 3.5 L16 block rows
3.2 2.5 2.0 1.5 1.2 0.9 0.7 meters
10.4 8.4 6.5 5.0 3.8 2.9 2.3 feet
10°
12.7 10.3 8.1 6.2 4.8 3.7 3.0 L16 block rows
2.5 2.1 1.6 1.2 1.0 0.7 0.6 meters
8.3 6.8 5.3 4.1 3.1 2.4 2.0 feet
22°
10.5 7.8 5.6 4.0 2.7 2.0 1.8 L16 block rows
2.1 1.6 1.1 0.8 0.5 0.4 0.4 meters
6.9 5.1 3.7 2.6 1.8 1.3 1.2 feet
 
Silty sand
&
sand
0°
24.6 19.0 14.3 10.6 7.9 6.1 5.2 L16 block rows
4.9 3.8 2.9 2.1 1.6 1.2 1.0 meters
16.1 12.5 9.4 7.0 5.2 4.0 3.4 feet
10°
21.8 16.5 12.2 8.9 6.4 4.9 4.3 L16 block rows
4.4 3.3 2.4 1.8 1.3 1.0 0.9 meters
14.3 10.8 8.0 5.8 4.2 3.2 2.8 feet
22°
16.9 12.8 9.4 6.8 4.8 3.6 3.2 L16 block rows
3.4 2.6 1.9 1.4 1.0 0.7 0.6 meters
11.1 8.4 6.2 4.5 3.1 2.4 2.1 feet

  1. Wall height measured from top of foundation / levelling pad.
  2. Top of foundation / levelling pad a minimum of 150mm / 0.5 ft below ground level
  3. No allowance made for surcharge above wall
  4. Angle of internal friction used in calculations: P(firm clay)>26°,P(silty sand)>32°.
  5. Compaction effort at optimum moisture content to ensure maximum density achievable.
  6. Provided that groundwater conditions are controlled, a wide variety of soil types can be used for infill soil.
  7. Subsoil drainage is essential to intercept groundwater. Build-up of hydrostatic pressure and seepage forces minimised.
  8. Surface water run-off should be directed away from the wall